Dublin City Weekly Planning08 Jul 2026

WEB2698/26

Nos. 16-19 Rutland Place, Dublin 1, (located to the rear of Nos 16-19 North Great George's Street all of which, are…

Lead potentialMedium

Amendments to a 26-unit apartment scheme with internal alterations, lift relocation, fenestration and roof changes; moderate defined scope.

Planning stageNew Application
Project typeRenovation Alteration
Development sectorResidential
Matched trades8

Source description

What is being proposed

PROTECTED STRUCTURE: Sevona Ltd. intend to apply for planning permission for amendments to DCC Reg. Ref. 3747/23 (ACP Ref. 319653-24) at this c. 0.0846ha site located at Nos. 16-19 Rutland Place, Dublin 1 (located to the rear of Nos. 16-19 North Great George’s Street, all of which are Protected Structures) (RPS Nos. 3191, 3192, 3193, and 3194). The proposed amendments are comprised of internal alterations to the permitted layout at first, second, and third floor levels to facilitate a revised unit mix of 4 No. Studio apartment units; 17 No. 1-Bedroom apartment units; 1 No. 2-Bedroom, 4-Person apartment unit; 3 No. 3-Bedroom, 4-Person apartment units; and 1 No.…

Read full source description

PROTECTED STRUCTURE: Sevona Ltd. intend to apply for planning permission for amendments to DCC Reg. Ref. 3747/23 (ACP Ref. 319653-24) at this c. 0.0846ha site located at Nos. 16-19 Rutland Place, Dublin 1 (located to the rear of Nos. 16-19 North Great George’s Street, all of which are Protected Structures) (RPS Nos. 3191, 3192, 3193, and 3194). The proposed amendments are comprised of internal alterations to the permitted layout at first, second, and third floor levels to facilitate a revised unit mix of 4 No. Studio apartment units; 17 No. 1-Bedroom apartment units; 1 No. 2-Bedroom, 4-Person apartment unit; 3 No. 3-Bedroom, 4-Person apartment units; and 1 No. 3-Bedroom, 5-Person apartment unit, representing an overall increase in the number of apartment units provided from 20 No. units to 26 No. units in total. The proposed amendments are also comprised of alterations and reconfiguration to the internal layout, including amendments to internal party walls at first, second, and third floor levels; Relocation of lift and A.O.V system at ground, first, second, and third floor levels; Modification to fenestration on front elevation to apartment unit A-1-04 at first floor level and apartment unit A-2-12 at second floor level consisting of the replacement of previously permitted single large opening at both levels with two smaller openings to reflect internal changes; The omission of previously permitted louvre openings to balconies on south-eastern side elevation at first, and second floor levels per Condition No. 5 of granted permission; Modification to building line at third floor and roof level to simplify the roof arrangement and remove previously permitted recesses; The omission of 2 No. previously permitted openings to the plant rooms on the north/south/east/west rear building façade; The addition of 8 No. bicycle parking spaces to the rear courtyard and relocation of stands; and all other associated development works above and below ground.

Opportunity fit

Why these trades match

8 evidence-led matches
01

Architecture Design

Medium

Amendments to a permitted scheme on a protected-structure site require architectural design.

02

Carpentry Joinery

Medium

Internal alterations to party walls and layout reconfiguration at multiple floor levels.

03

Concrete Masonry

Medium

Amendments to internal party walls at first, second and third floor levels explicitly described.

04

Electrical

Medium

Relocation of lift and A.O.V system at multiple floor levels implies electrical works.

05

Main Contracting

Medium

Amendments to a 26-unit apartment development with internal alterations, lift relocation and fenestration changes.

06

Roofing

Medium

Modification to building line at third floor and roof level to simplify the roof arrangement described.

07

Structural Engineering

Medium

Internal party wall amendments and roof modifications on a protected-structure site require structural input.

08

Windows Doors

Medium

Modification to fenestration on front elevation and replacement of single large openings with two smaller openings described.